Solid State Relay
No Contact & Long Life, Stable Control
Solid State Relay
XSSVR-VA W2 Modulating Type Single-Phase AC Solid State Regulator

The XSSVR-W2 is a voltage-controlled single-phase AC solid state regulator designed for precise proportional power control of AC loads. Supporting standard 0–5VDC and 0–10VDC analog input signals, the regulator enables smooth adjustment of output voltage and power for industrial heating systems, temperature control equipment, lighting control, and automation applications. Featuring opto-electronic isolation, bidirectional thyristor output, built-in RC snubber protection, and LED status indication, the XSSVR-W2 delivers reliable performance, accurate regulation, and long-term operational stability.

Control Signal: 0–5VDC / 0–10VDC

Load Voltage: 0–240VAC

Rated Load Current: 10A–120A

2e68a3da4c690a02.webp

Product Features
  • Compact Industrial Design
    Compact Industrial Design

    Compact screw-mount structure simplifies installation and integration into industrial control panels and equipment.

  • LED Operating Indicator
    LED Operating Indicator

    Built-in LED indicator allows easy visual monitoring of operating status.

  • Built-In RC Snubber Circuit
    Built-In RC Snubber Circuit

    Integrated RC protection circuit helps suppress voltage transients and improve long-term operating reliability.

  • Opto-Electronic Isolation
    Opto-Electronic Isolation

    Input and output circuits are electrically isolated to improve system safety and enhance resistance to electrical interference.

  • Bidirectional Thyristor Output
    Bidirectional Thyristor Output

    Employs bidirectional thyristor technology for stable, efficient, and reliable AC load regulation.

  • Proportional Power Regulation
    Proportional Power Regulation

    Provides smooth and continuous adjustment of AC output voltage and power according to the input signal for accurate process control.

  • Standard Analog Voltage Control
    Standard Analog Voltage Control

    Compatible with 0–5VDC and 0–10VDC control signals, allowing direct integration with PLCs, controllers, sensors, and automation systems.

Specifications
Product modelXSSVR-VA□□W2
Input control0-10VDC; 0-5VDC
Load voltage0-240VAC
Load max current10A-120A
Load mini current0.05A
Breakover voltage≤2VAC
Output leakage current≤5mA
Medium withstand voltage≥2500VAC
Insulating resistance≥100MΩ
Frequency range47-63Hz
Operating temperature-20-70℃
Load current safety factor
Resistive load 50-60%
Inductive load 30-40%
Product Certification
  • 01Certification for the Chinese market

    Compliant with GB national standards, with CCC and CQC certification for domestic sales and bidding compliance.

    Certification for the Chinese market Certification for the Chinese market
  • 02EU Market Certification

    Comply with CE, RoHS, REACH and EN standards, approved by TÜV & VDE, and support ATEX certification for explosive hazardous areas.

    EU Market Certification EU Market Certification EU Market Certification
  • 03North American Market Certification

    UL, CUL and CSA certified, conforming to North American electrical safety specifications for US and Canada market access.

    North American Market Certification
  • 04Japanese, Korean, and Asian markets

    Adapt to Japanese PSE and Korean KC certification, follow JIS and KS local standards to meet market access regulations of Japan and South Korea.

    Japanese, Korean, and Asian markets
Product Introduction & Process
  • 1
    Electronic Component Inspection

    Optocouplers, thyristors, triacs, MOSFETs, IGBTs, diodes, resistors, capacitors, varistors, LEDs, transformers, terminal blocks, ceramic substrates, PCBs, and aluminum heat sinks are inspected before production. Electrical parameters and supplier batch information are verified.

    2
    Power Device Selection and Matching

    Power semiconductor devices are screened according to blocking voltage, trigger characteristics, leakage current, on-state voltage, current capacity, and thermal performance. Components are matched according to the required relay voltage and current rating.

    3
    PCB or Power Substrate Preparation

    Printed circuit boards, ceramic substrates, or metal-based power substrates are cleaned and inspected. Solder pads, conductive tracks, insulation distances, and mounting surfaces are checked before electronic assembly.

    4
    SMT Component Placement

    Solder paste is accurately printed onto the PCB. Surface-mount components are positioned by automated placement equipment and soldered through a controlled reflow process. Temperature profiles are monitored to prevent insufficient soldering or thermal damage.

    5
    Through-Hole Component Assembly

    Power semiconductors, optocouplers, terminal blocks, transformers, LEDs, and other through-hole components are inserted according to the circuit design. Components are wave-soldered or manually soldered using controlled temperature and soldering time.

    6
    Solder Joint Inspection

    Solder joints are inspected visually or through automated optical inspection. The inspection checks for insufficient solder, bridging, cold joints, component misalignment, polarity errors, and contamination.

    7
    Circuit Cleaning and Preliminary Testing

    Flux residue and contaminants are removed where required. The assembled circuit is tested for input response, output switching, polarity, LED indication, short circuits, and basic insulation performance before encapsulation.

    8
    Heat Dissipation Assembly

    Power devices are mounted onto aluminum heat sinks, metal bases, or thermally conductive housings. Thermal grease, insulation pads, ceramic sheets, and controlled fastening torque are used to achieve reliable heat transfer while maintaining electrical isolation.

    9
    Protection Circuit Installation

    Depending on the model, RC snubber circuits, MOV surge protectors, transient suppression devices, over-temperature protection, or monitoring circuits are installed and verified.

    10
    Potting and Encapsulation

    The electronic assembly is positioned inside the housing and filled with insulating epoxy or thermally conductive encapsulating material. Vacuum treatment may be used to reduce trapped air. The resin is cured under controlled temperature and time conditions.

    11
    Electrical Performance Testing

    Each relay is tested for input trigger voltage, release voltage, input current, output leakage current, on-state voltage drop, zero-crossing characteristics, random-trigger response, insulation resistance, and dielectric strength.

    12
    Load and Thermal Testing

    The relay is operated under a specified load to verify switching stability and heat dissipation. Case temperature, semiconductor temperature rise, terminal temperature, and output waveform are monitored during testing.

    13
    Burn-In and Reliability Screening

    Selected models or production batches undergo continuous powered operation, repeated switching, high-temperature aging, or thermal cycling. Unstable components and early-life failures are identified before shipment.

    14
    Final Inspection and Packaging

    Terminal torque, housing condition, labels, current ratings, control voltage markings, wiring identification, and mounting accessories are checked. Approved products receive batch codes and are packed with appropriate electrostatic and mechanical protection.

Download
  • All
  • Selection Guide
  • Product Manual
  • Outline Drawing
Application Scenarios
Customization & Delivery
We support the following types of customization
  • Electrical Parameter Customization :

    Custom voltage & current, AC/DC type, zero-cross or random trigger.

  • Mounting Structure Customization :

    Custom mounting, terminals and non-standard dimensions.

  • Heat Dissipation & Protection Customization :

    Custom heat dissipation, high isolation, potting and anti-corrosion protection.

  • Function Upgrade Customization :

    Overheat/overcurrent protection, anti-interference, delay and soft start optional.

  • Appearance & Brand Customization

    Custom logo, marking, OEM/ODM and personalized solution design.

  • Proofing Cycle

    Regular customization: 3-7 working days

    Complex Customization: 7-15 working days

    Urgent Sampling: 24-72 hours

  • Proofing Cost ( $ )

    2222 US dollars

  • MOQ

    Conventional products have no minimum order quantity. Customized products can be consulted with customer service

  • Delivery Time

    The delivery time usually varies depending on the quantity and model of the order, usually 3-5 days. For specific times, please consult us

Frequently Asked Questions
  • How can I get an accurate quotation?
  • What is not covered by the warranty?
  • What does the product warranty cover?
  • What is your standard production lead time?
  • Which certifications and compliance documents are available?
  • Can you support samples and small trial orders?
  • What customization services do you offer?
  • How long does custom sample development take?
  • How are custom sample costs calculated?
  • How do you ensure product traceability?
  • What quality inspections are performed?
Related Recommendations